Presentations

Publication(English)  2011

Neuro_Group

Katakami N, Inaba Y, Sugata S, Tsurusaki M, Itho T, Machida T, Tanaka H, Nakayama T, Moriwaki T, Breuer J, Aitoku Y. Magnetic resonance evaluation of brain metastases from systemic malignances with two doses of Gadobuturol 1.0 M compred with gadoteridol. A multicenter, phase II/III Study in Patients with known or suspected brain metastases. Investigative Radiology, 46: 411-18, 2011

Kuroda J, Kinoshita M, Tanaka H, Nishida T, Nakamura H, Watanabe Y, Tomiyama N, Fujinaka T, Yoshimine T.  Cardiac Cycle-Related Volume Change in Unruptured Cerebral Aneurysms: A Detailed Volume Quantification Study Using 4-Dimensional CT Angiography. Stroke 2011 [E-pub ahead Oct 13]

Nakazawa T, Watanabe Y, Hori Y, Kiso K, Higashi M, Itoh T, Naito H. Lung perfused blood volume images with dual-energy computed tomography for chronic thromboembolic pulmonary hypertension: correlation to scintigraphy with single-photon emission computed tomography. J Comput Assist Tomogr. 35(5):590-5, 2011

Nishida T, Kinoshita M, Tanaka H, Fujinaka T, Yoshimine T. Visualization and numerical quantification of cardiac cycle-related physiological motions of the cerebral arteries in humans. AJNR Am J Neuroradiol. 32(11):E206-8, 2011 Epub 2011 Feb 24

Takahashi H, Tanaka H, Fujita N, Murase K, Tomiyama N. Variation in supratentorial cerebrospinal fluid production rate in one day: measurement by nontriggered phase-contrast magnetic resonance imaging. Jpn J Radiol. 29(2):110-5, 2011

Watanabe Y, Makidono A, Nakamura M, Saida Y. 3D-MR cisternography for the identification of distal dural rings; Comparison of 3D-CISS (Constructive Interference in Steady State) and 3D-SPACE (Sampling Perfection with Application optimized Contrasts using different flip angle Evolutions) sequences. Magnetic Resonance in Medical Sciences, 10(1):29-32, 2011

Watanabe Y, Nakazawa T, Higashi M, Itoh T, Naito H. Assessment of Calcified Carotid Plaque Volume: Comparison of Contrast-Enhanced Dual-Energy CT Angiography and Native Single-Energy CT. AJR Am J Roentgenol. 196(6):W796-9, 2011

Chest_Group

Honda O, Yanagawa M, Inoue A, Kikuyama A, Yoshida S, Sumikawa H, Tobino K, Koyama M, Tomiyama N. Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction. Br J Radiol. 84(1000):335-41, 2011

Inoue M, Honda O, Tomiyama N, Minami M, Sawabata N, Kadota Y, Shintani Y, Ohno Y, Okumura M. Risk of pleural recurrence after computed tomographic-guided percutaneous needle biopsy in stage I lung cancer patients. Ann Thorac Surg. 91(4):1066-71, 2011

Kim HJ, Lee KS, Johkoh T, Tomiyama N, Lee HY, Han J, Kim TS. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT-pathology comparisons and evolutional changes at CT. Eur Radiol. 21:1406-1415, 2011

Sumikawa H, Johkoh T, Fujimoto K, Ichikado K, Colby TV, Fukuoka J, Taniguchi H, Kondoh Y, Kataoka K, Yanagawa M, Koyama M, Honda O, Tomiyama N.Usual interstitial pneumonia and nonspecific interstitial pneumonia: Correlation between CT findings at the site of biopsy with pathological diagnoses. Eur J Radiol. 2011 Dec 12. [Epub ahead of print]

Tobino K, Gunji Y, Kurihara M, Kunogi M, Koike K, Tomiyama N, Johkoh T, Kodama Y, Iwakami SI, Kikkawa M, Takahashi K, Seyama K. Characteristics of pulmonary cysts in Birt-Hogg-Dube syndrome: thin-section CT findings of the chest in 12 patients. Eur J Radiol. 77: 403-409, 2011

Ueguchi T, Yamada S, Mihara N, Koyama Y, Sumikawa H, Tomiyama N. Breast diffusion-weighted MRI: comparison of tetrahedral versus orthogonal diffusion sensitization for detection and localization of mass lesions. J Magn Reson Imaging. 33(6):1375-1381, 2011

Yanagawa M, Tomiyama N. Prediction of thymoma histology and stage by radiographic criteria. Thorac Surg Clin. 21: 1-12, 2011

Yanagawa M, Honda O, Kikuyama A, Gyobu T, Sumikawa H, Koyama M, Tomiyama N. Pulmonary nodules: Effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system-Comparison of performance between different-dose CT scans. Eur J Radiol. 2011 Oct 5. [Epub ahead of print]

Watabe T, Tatsumi M, Watabe H, Isohashi K, Kato H, Yanagawa M, Shimosegawa E, Hatazawa J. Intratumoral heterogeneity of F-18 FDG uptake differentiates between gastrointestinal stromal tumors and abdominal malignant lymphomas on PET/CT. Ann Nucl Med. 2011 Dec 21. [Epub ahead of print]

Abdominal Imaging & Interventional Radiology_Group

Foruzan AH, Zoroofi RA, Sato Y, Hori M. A Hessian-based filter for vascular segmentation of noisy hepatic CT scans. Int J Comput Assist Radiol Surg. 2011 Jul 10. [Epub ahead of print]

Fujwara K, Yoshino K, Enomoto T, Fujita M, Ueda Y, Miyatake T, Kimura T, Muraji M, Fujita H, Kimura T, Hori M. Usefulness of computed tomography in predicting cytoreductive surgical outcomes for ovarian cancer. Arch Gynecol Obstet. 284(6):1501-7, 2011

Hidaka K, Moine L, Collin G, Labarre D, Louis Grossiord J, Huang N, Osuga K, Wada S, Laurent A. Elasticity and viscoelasticity of embolization microspheres. J Mech Behav Biomed Mater. 4(8):2161-7, 2011

Higashihara H, Osuga K, Ueguchi T, Onishi H, Tanaka H, Maeda N, Tomoda K, Tomiyama N. Usefulness of contrast-enhanced three-dimensional MR angiography using time-resolved imaging of contrast kinetics applied to description of Extracranial Arteriovenous Malformations: Initial Experience. Eur J Radiol; 2011 Apr 5. [Epub ahead of print]

Higashihara H, Osuga K, Onishi H, Nakamoto A, Tsuboyama T, Maeda N, Hori M, Kim T, Tomiyama N. Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT. Eur Radiol. 2011 Nov 26. [Epub ahead of print]

Higashihara H, Osuga K, Azuma T, Nakazawa T, Yanagawa M, Kikuyama A, Maeda N, Tomiyama N. Detection of pulmonary nodules by C-arm CT using a phantom lung: comparison with CT. Acta Radiol. 52(9): 964-8, 2011

Hori M, Kim T, Onishi H, Ueguchi T, Tatsumi M, Nakamoto A, Tsuboyama T, Tomoda K, Tomiyama N. Uterine Tumors: Comparison of 3D versus 2D T2-weighted Turbo Spin-Echo MR Imaging at 3.0 T – Initial Experience. Radiology. 258(1):154-63, 2011

Hori M, Suzuki K, Epstein ML, Baron RL. Computed tomography liver volumetry using 3-dimensional image data in living donor liver transplantation: Effects of the slice thickness on the volume calculation. Liver Transpl. 17(12):1427-36, 2011

Katsube T, Okada M, Kumano S, Imaoka I, Kagawa Y, Hori M, Ishii K, Tanigawa N, Imai Y, Kudo M, Murakami T.Estimation of liver function using T2* mapping on gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid enhanced magnetic resonance imaging. Eur J Radiol. 2011 Apr 20. [Epub ahead of print]

Katsube T, Okada M, Kumano S, Hori M, Imaoka I, Ishii K, Kudo M, Kitagaki H, Murakami T. Estimation of Liver Function Using T1 Mapping on Gd-EOB-DTPA-Enhanced Magnetic Resonance Imaging. Invest Radiol. 46(4):277-83, 2011

Maeda N, Osuga K, Higashihara H, Tomoda K, Mikami K, Nakazawa T, Nakamura H, Tomiyama N. Transarterial chemoembolization with cisplatin as second-line treatment for hepatocellular carcinoma unresponsive to chemoembolization with epirubicin-Lipiodol emulsion. Cardiovasc Intervent Radiol. 2011 Jan 4. [Epub ahead of print]

Maeda N, Osuga K, Shimazu K, Morii E, Mikami K, Hori S, Nakazawa T, Higashihara H, Tomoda K, Nakamura H, Tomiyama N. In vivo evaluation of cisplatin-loaded superabsorbent polymer microspheres for use in chemoembolization of VX2 liver tumors. J Vasc Interv Radiol. 2011 Dec 29. [Epub ahead of print]

Nagano H, Wada H, Kobayashi S, Marubashi S, Eguchi H, Tanemura M, Tomimaru Y, Osuga K, Umeshita K, Doki Y, Mori M. Long-term outcome of combined interferon-α and 5-fluorouracil treatment for advanced hepatocellular carcinoma with major portal vein thrombosis. Oncology. 80(1-2):63-9, 2011

Nakaya Y, Kim T, Hori M, Onishi H, Nakamoto A, Tsuboyama T, Maeda N, Higashihara H, Tomoda K, Nakamura H. Correlations between aorto-popliteal bolus transit speed and aortic and popliteal bolus transit time during CT angiography of aortoiliac and lower extremity arteries. Eur J Radiol. 79(2):272-276, 2011

Nakazawa T, Watanabe Y, Hori Y, Kiso K, Higashi M, Itoh T, Naito H. Lung Perfused Blood Volume Images With Dual-Energy Computed Tomography for Chronic Thromboembolic Pulmonary Hypertension: Correlation to Scintigraphy With Single-Photon Emission Computed Tomography. J Comput Assist Tomogr. 35(5):590-5, 2011

Onishi H, Murakami T, Kim T, Hori M, Osuga K, Tatsumi M, Higashihara H, Maeda N, Tsuboyama T, Nakamoto A, Tomoda K, Tomiyama N. Abdominal multi-detector row CT: effectiveness of determining contrast medium dose on basis of body surface area. Eur J Radiol. 80(3):643-7, 2011

Onishi H, Kim T, Imai Y, Hori M, Nagano H, Nakaya Y, Tsuboyama T, Nakamoto A, Tatsumi M, Kumano S, Okada M, Takamura M, Wakasa K, Tomiyama N, Murakami T. Hypervascular hepatocellular carcinomas: detection with gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Eur Radiol. 2011 Nov 7. [Epub ahead of print]

Suzuki K, Epstein ML, Kohlbrenner R, Garg S, Hori M, Oto A, Baron RL. Quantitative Radiology: Automated CT Liver Volumetry Compared With Interactive Volumetry and Manual Volumetry. AJR Am J Roentgenol. 197(4):W706-W712, 2011

Radiation Oncology_Group

放射線治療学講座のホームページの業績(英文)をご参照ください。